codesys-mcp-toolkit
Model Context Protocol server for CODESYS automation platform
Safety scan
A static text scan, not a guarantee. Select the badge to see what was scanned and every finding.
Check it deeper on your machine
It has changed since its scan on 11 Nov 2026.
As a Claude Code plugin, install it and then ask Claude Code:
/plugin marketplace add keithmackay/mackayi/plugin install scanskillsafety@mackayiDo a deep scan of https://github.com/johannesPettersson80/codesys-mcp-toolkit with scanskillsafety
Or from a terminal, clone it and run it:
git clone https://github.com/keithmackay/scanskillsafety-skill ~/.claude/skills/scanskillsafetynode ~/.claude/skills/scanskillsafety/cli.cjs --deep 'https://github.com/johannesPettersson80/codesys-mcp-toolkit'
It checks the exact commit: every file, its packages against OSV (api.osv.dev), how it compares with this page's scan (findsafeskills.com receives the repository's address), and, if you agree, Claude reading every file with your own Claude subscription. It never runs the code.
Badge for your README
Markdown
[](/listings/johannespettersson80--codesys-mcp-toolkit)HTML
<a href="/listings/johannespettersson80--codesys-mcp-toolkit"><img src="/api/listings/johannespettersson80--codesys-mcp-toolkit/badge.svg" alt="findsafeskills safety rating" /></a>Install
Install instructions from the README
As written by the repo's author. findsafeskills has not verified these steps.
The recommended way to install is globally using npm:
npm install -g @codesys/mcp-toolkit
This installs the package globally, making the `codesys-mcp-tool` command available in your system's terminal PATH.
*(Advanced users can also install from source for development - see CONTRIBUTING.md if available).*
What was scanned
The files the safety scan read, as written by the repository's author and shown as plain text. Lines with a finding are marked.
README.md · README · 573 lines
View this file on GitHub (read at the repository's current version: the scan did not record which commit it read)
This file has changed since it was scanned, so this is not exactly the text that was scanned, and no line is marked. The findings are listed with the safety scan above.
- <div align="center">
- # CODESYS MCP Toolkit
- **Let Claude, or any MCP client, read, write, compile and simulate Structured Text in your CODESYS V3.5 projects.**
- English | [简体中文](README.zh-CN.md)
- [](LICENSE)
- [](https://www.npmjs.com/package/@codesys/mcp-toolkit)
- 
- 
- 
- [](https://modelcontextprotocol.io)
- </div>
- An [MCP](https://modelcontextprotocol.io) server that keeps one CODESYS session
- open in the background and gives Claude, or any MCP client, direct access to
- it. Claude works on your real project with the real CODESYS compiler, and you
- can watch the code change as it happens.
- 
- ## Highlights
- - **Edits your real project.** POUs, methods, properties, interfaces, DUTs and
- GVLs, as Structured Text.
- - **Compiles with the real compiler.** Errors come back with object, line and
- code, including in code that no task calls yet.
- - **Tests in simulation.** Run, step exact cycles, read, write and force values
- in CODESYS's own simulation, with nothing else to install.
- - **Understands the project.** Outlines, I/O lists, the device tree and library
- interfaces, without reading every object.
- - **Shows its work.** A live panel with the project tree, the code as it is
- written, compile results, and Accept or Revert for each change.
- - **Designs operator screens.** Claude builds a live HMI for your program:
- an overview of the line's stations, process diagrams with ISO 10628-2
- symbols and ISA-5.1 instruments, clear state signs, values, trends and
- alarms. It looks at the result and polishes it. You operate it in the
- browser against the simulation, it exports as a native CODESYS
- visualization with real CODESYS alarms, and as a P&ID sheet for the
- documentation.
- - **Ready for handover.** A project report with a commissioning checklist
- built from the project, and a plain-text export of every object for git.
- - **Never touches a real controller.** The only online connection is to
- CODESYS's own simulation, and every online call checks for it first.
- ## Quick start
- ### Requirements
- - Windows with **CODESYS V3.5** and its **Scripting** add-on. Tested with SP21
- and SP22 on Scripting 4.2, and SP21 on 4.1. SP16 and later should work.
- - **Node.js 20** or later.
- Schneider EcoStruxure Machine Expert V2.3 (`LogicBuilder.exe`, Scripting 4.1)
- works too: pass `--codesys-path` and leave out `--codesys-profile`, since Machine
- Expert has no profiles. See the [Machine Expert notes](docs/machine-expert-testing.md).
- ### Install
- ```bash
- npm install -g @codesys/mcp-toolkit
- ```
- Coming from version 1? The tools have changed: see
- [Migrating from v1](#migrating-from-v1).
- ### Connect it to Claude Desktop
- Add the server to `%APPDATA%\Claude\claude_desktop_config.json`, then restart
- Claude Desktop:
- ```json
- {
- "mcpServers": {
- "codesys": {
- "command": "codesys-mcp-tool",
- "args": [
- "--codesys-path", "C:\\Program Files\\CODESYS 3.5.21.0\\CODESYS\\Common\\CODESYS.exe",
- "--codesys-profile", "CODESYS V3.5 SP21",
- "--workspace", "C:\\PLC\\Projects"
- ]
- }
- }
- }
- ```
- `--codesys-path` and `--codesys-profile` are optional. Without them the server
- uses the newest CODESYS install under Program Files and its newest profile.
- Using OpenCode, Cursor, Cline or another client, or a model such as DeepSeek or
- Qwen? See [Other clients and models](#other-clients-and-models).
- ### Try it
- > Create a project called `BlinkDemo.project`. Add a function block that toggles
- > an output once per second, call it from `PLC_PRG`, compile it, and prove in
- > simulation that the output toggles.
- CODESYS starts in the background when the server launches. A cold start takes
- 1 to 3 minutes; later starts take about 10 seconds.
- Claude Desktop asks for approval per tool. Choose **Always allow** the first
- time it asks about `codesys`, and once more for `open_sim_panel`. After that it
- doesn't ask again.
- ## What Claude can do
- Everything goes through one MCP tool, `codesys`, with an action for each
- operation. [The reference](docs/reference.md) describes each one.
- | Area | Actions |
- | --- | --- |
- | **Projects** | `open_project` `create_project` `save_project` `close_project` `codesys_status` |
- | **Read code** | `get_project_tree` `read_objects` `search_code` `get_outline` |
- | **Change code** | `write_object` `create_object` `create_graphical` `delete_object` `rename_object` |
- | **Build** | `compile` |
- | **Libraries** | `find_library` `list_libraries` `add_library` `pin_library` `remove_library` `get_library_api` `get_signature` |
- | **Navigate code** | `find_references` `rename_symbol` |
- | **Tasks and I/O** | `list_tasks` `configure_task` `get_io_list` `get_devices` `find_device` `add_device` `device_parameters` `configure_device` |
- | **Change tracking** | `checkpoint` `get_changes` `revert_object` |
- | **Simulation** | `codesys_sim_start` `codesys_sim_stop` `codesys_sim_status` `codesys_sim_control` `codesys_sim_cycle` `codesys_sim_read` `codesys_sim_write` `codesys_sim_force` `codesys_sim_unforce` `codesys_sim_test` |
- | **Trace** | `trace_setup` `trace_record` |
- | **Debug** | `breakpoint_set` `breakpoint_on_change` `breakpoint_clear` `debug_status` `debug_step` `debug_continue` `watch` |
- | **HMI screens** | `hmi_save_screen` `hmi_template` `hmi_screenshot` `hmi_export_codesys` `hmi_list` `hmi_delete_screen` `open_hmi` `hmi_save_symbol` `hmi_symbols` `hmi_delete_symbol` `hmi_translate` `hmi_pid` |
- | **Alarms** | `alarm_list` `alarm_status` `alarm_acknowledge` `alarm_history` `create_alarm_history` |
- | **Handover** | `project_report` `export_sources` `compare_sources` `create_recipes` |
- | **Helpers** | `batch` `wait` `help` `open_workspace` `show_in_codesys` |
- `batch` runs up to 50 actions in one call, which is much faster than separate
- calls.
- Some actions go beyond what CODESYS's scripting API documents and use CODESYS's
- own services inside the IDE: `get_signature`, `find_references`,
- `rename_symbol`, `trace_setup`, `trace_record`, the debug actions,
- `hmi_export_codesys` (with its alarms and user groups), the alarm actions and
- `--show-window`.
- They are **experimental**: checked on CODESYS V3.5 SP21 and SP22 as noted in
- the [changelog](CHANGELOG.md). On another version they may report that the
- feature isn't available, or not work. They don't depend on CODESYS's
- language: the native HMI export was checked with a German and a Chinese user
- interface too.
- Claude writes Structured Text, and creates ladder (LD), FBD, CFC and SFC
- programs and function blocks with `create_graphical` from a simple description
- of rungs, networks or steps; CODESYS draws them. SFC charts can have alternative
- and parallel branches and jumps. Reading an LD, FBD, CFC or SFC POU gives the
- same description, so Claude can change existing graphical code too: it edits the
- description and sends it back with `replace: true`.
- ## Live panel
- Right after opening or creating a project, Claude opens the panel as a card in
- the chat. It shows the status, the object Claude is working on and how many
- objects changed. **Open workspace** expands it into a CODESYS-style view with
- the project tree, editor tabs, compile problems and a review list.
- From the panel you can **Accept** or **Revert** each change, compare it with
- the version you last reviewed, and **Pause Claude** while you look around.
- 
- The card needs a client that supports
- [MCP Apps](https://modelcontextprotocol.io/extensions/apps). In our testing
- Claude Desktop draws it in the Code tab but not in a normal chat
- ([anthropics/claude-ai-mcp#1243](https://github.com/anthropics/claude-ai-mcp/issues/1243)).
- Ask Claude to open the workspace in your browser if you'd rather have it there;
- the browser never opens by itself.
- [More about the panel](docs/reference.md#live-panel)
- ## HMI screens
- Ask Claude for operator screens and it designs them for your program: an
- overview of the line's stations, process diagrams, values with their
- set-points, trends and alarms, all bound to your PLC variables. The look is a
- calm, flat design system (Siemens iX colours, high-performance HMI practice
- after ISA-101): colour means a state or something to act on, never decoration.
- 
- - **The machine in the frame.** Its state (Production, Fault, Stopped, ...)
- sits in the top bar's corner with a thin line in its colour under the bar;
- Start, Stop, Reset and the Manual/Auto switch in a bar along the bottom; the
- active faults, warnings and messages counted in the top bar; the pages in a
- rail on the left. `hmi_template` gives Claude a good layout for each kind of
- page. Panels: 1280x720, 1920x1080, 1024x768 or 800x480.
- - **An overview of the stations.** A `line` card draws the process as station
- tiles on a product path, each with its pictogram, key value and state; a
- supply such as steam joins its station from above, and tapping a tile opens
- its page.
- - **Process diagrams to the standards.** Symbols drawn from ISO 10628-2 (pumps,
- fans, valves, check and control valves, heat exchangers, motors on the
- machine they drive, agitators, separators, filters, conveyors and more),
- instruments as ISA-5.1 bubbles outside the vessel and joined to where they
- measure, and pipes that route themselves between named ports
- (`T-201.right`, `P-201.in`) with line names and flow arrows at the edges.
- - **State at a glance, without clutter.** Three separate things, each with its
- own sign, so none hides another: the run state before the name (▶ running,
- ■ stopped), the mode after it (a hand in Manual; Auto shows nothing) and the
- condition at the symbol's corner (an amber warning or a red alarm; OK shows
- nothing). A tripped switch (LSH, PSL) gets the same badge at its bubble. A
- closed valve is drawn filled, as on a P&ID. Symbols are never
- filled grey or coloured by state, and nothing moves.
- - **Labels place themselves.** Every name, line name and reading is put where
- it touches no pipe, equipment or other text and stays inside the card; a
- tank's name goes inside the vessel. A value that belongs to a piece of
- equipment, such as a control valve's opening, is shown under its name.
- - **Claude checks its own work.** Saving a screen checks the layout (overlaps,
- labels without room) and that the diagram is a process: equipment no pipe
- reaches, an inlet without an outlet, a heat exchanger with one circuit,
- instruments inside a vessel, a motor that drives nothing, a reading drawn
- as a separate sensor when it belongs to equipment, or a run state on a
- filter. `hmi_screenshot` returns the screen as an image to look at.
- - **Your own symbols.** Claude can draw a symbol you need as SVG, or import
- yours from an SVG file (`hmi_save_symbol`), and gets back a picture of it
- with its ports. Custom SVG is checked against a short list of elements and
- attributes: scripts, styles, links and external images are refused.
- - **Live in your browser.** Ask Claude to open the HMI (`open_hmi`). The page
- is served by the toolkit on 127.0.0.1 with a token, like the workspace.
- While CODESYS's simulation runs it shows live values and trends, and
- buttons, switches and setpoints write to the simulation, so you can operate
- your program before any hardware exists.
- - **Light, dark and high-contrast themes,** the same on every page; `accent`
- puts your company colour on the highlights, and text on it turns black or
- white to stay readable. Screens are saved next to the project as
- `<project>.hmi.json`, so they travel with it and can go into version
- control.
- 
- 
- 
- The HMI writes only into CODESYS's own simulation, like the rest of the
- toolkit. Screenshots use Microsoft Edge or Google Chrome, whichever is
- installed.
- ### P&ID sheet
- `hmi_pid` exports a screen's process diagram as an engineering P&ID drawing
- for documentation and commissioning: the same diagram drawn black on white,
- with nothing live, on an A3 sheet with a frame, a legend of the symbols it
- uses and a title block (drawing number, revision, date). It is saved next to
- the project as PDF, SVG or PNG. Since it comes from the HMI's own diagram,
- there is no second drawing to keep up to date.
- 
- ### As a native CODESYS visualization
- `hmi_export_codesys` builds the same screens as real CODESYS visualizations in
- your project. They are ordinary visualization objects, so they go with the
- application like ones you drew yourself (checked in CODESYS's simulation, not
- on a controller): the same frame, cards, symbols, state signs, labels and
- station tiles as in the browser, drawn with CODESYS's own elements and
- pictures in an embedded image pool. A generated program, `PRG_HMI_<screen>`,
- works out what the pictures need (scaled bars and levels, the machine state,
- alarm counts). Claude gets a picture of the result.
- 
- 
- A multi-page HMI comes out as one visualization per page with the rail of
- page buttons, the first page as the start page of TargetVisu and WebVisu at
- the panel size, faceplates as CODESYS dialogs, the pages' alarms in CODESYS's
- alarm management (Alarm Configuration, with timestamps and acknowledge in the
- PLC), and user groups (Operator, Maintenance, Admin) behind a Login button.
- Users and passwords are yours to add in the Visualization Manager.
- A tile can be limited to a group and up: `access: {min: 'Maintenance'}` lets
- lower groups see it without operating it, `below: 'hide'` hides it from them.
- The rights go on CODESYS's own elements and also apply when nobody is logged
- in.
- The alarms are CODESYS's own, not a copy in the HMI: an alarm group with its
- observations, classes and messages, which CODESYS's alarm manager evaluates in
- the PLC. In the simulation, raising the fault made the group report an active
- alarm, and it stayed pending after the fault cleared, until acknowledged, as an
- Error-class alarm should.
- 
- Claude can test them in the simulation: `alarm_status` reads each alarm's
- state from CODESYS's alarm manager (normal, active, active acknowledged,
- cleared but waiting for confirmation or acknowledgement), and
- `alarm_acknowledge` acknowledges as an operator would. In the browser HMI and
- in CODESYS, an alarm row stays until it is acknowledged, with the time it
- came, its state and an acknowledge button.
- CODESYS's runtime alarm forgets its times once it is normal again, so the
- export also adds an alarm history to the PLC: generated ST that records every
- state change of every alarm (with CODESYS's own time of the change) in a
- RETAIN ring buffer. `alarm_history` lists it, and an alarms tile with
- `history: 5` shows the last events, in the browser and in CODESYS
- (`create_alarm_history` adds the same to a project with alarms of its own).
- Gauges are the same arc gauge as in the browser (pictures in the image pool,
- one per 2.5 % of the range), not CODESYS's chrome meter. Trends show their
- current values: a CODESYS trend needs a trend recording that scripting can't
- create yet. Checked on CODESYS V3.5 SP21 in the simulation. A visualization
- needs the `FloatingPointUtils` library in CODESYS's library repository; if
- it's missing, the export says so before it builds anything. A long export
- reports its progress (each page, the alarms, the compile) to clients that
- show MCP progress.
- ## Handover and version control
- `project_report` writes a Markdown report next to the project for whoever
- commissions or takes over the machine: a summary, the tasks, the I/O list and
- device-tree mappings, the CODESYS alarms, the HMI pages, libraries, devices and
- the program structure. It ends with a commissioning checklist built from the
- project itself: every task's cycle time, every input and output, every mapped
- channel, every alarm, every HMI page and the persistent variables to check on
- the real machine, plus the safety and archiving items no checklist should
- skip. Everything Claude did was tested in CODESYS's simulation only, and the
- report says so.
- `export_sources` writes the project as plain text for git: one `.st` file per
- POU, method, property, action, DUT, GVL and interface, in folders like the
- project tree, ladder/FBD/SFC bodies as PLCopenXML, a `project.txt` with tasks,
- libraries, devices and alarms, and the HMI screens. A `.project` file is
- binary; this folder is what makes a change reviewable as a diff. Exporting
- again rewrites only what changed and removes the files of deleted objects.
- `compare_sources` compares the open project with such a folder or with another
- `.project` file: the objects only in one of them, and a line diff of each
- changed one.
- ## Other clients and models
- The server works with any MCP client, not only Claude. For
- [OpenCode](https://opencode.ai), put this in `opencode.json` in your project
- folder (or in `~/.config/opencode/opencode.json`):
- ```json
- {
- "$schema": "https://opencode.ai/config.json",
- "mcp": {
- "codesys": {
- "type": "local",
- "command": [
- "codesys-mcp-tool",
- "--codesys-path", "C:\\Program Files\\CODESYS 3.5.22.40\\CODESYS\\Common\\CODESYS.exe",
- "--codesys-profile", "CODESYS V3.5 SP22 Patch 4",
- "--workspace", "C:\\PLC\\Projects"
- ],
- "enabled": true
- }
- }
- }
- ```
- `opencode mcp list` should then show `codesys` as connected. Clients that read
- an `mcpServers` file (Cursor, Cline, VS Code and others) take the same
- `command` and `args` as the Claude Desktop example above.
- Tested on 13 November 2026 with OpenCode 1.19.5 and CODESYS V3.5 SP22: each of
- these models created a project, read and changed `PLC_PRG`, compiled, listed
- libraries and devices, and ran the simulation, without help.
- | Model | Result |
- | --- | --- |
- | DeepSeek V4.1 Flash | All steps passed |
- | Qwen 3.6 Plus | All steps passed |
- | GLM 5.3 | All steps passed |
- | MiniMax M3 | All steps passed |
- 
- The live panel needs a client that shows MCP Apps cards (see
- [Live panel](#live-panel)). In other clients `open_sim_panel` does nothing
- visible; ask the model to open the workspace (`open_workspace`) to get the same
- view in your browser, or start the server with
- [`--show-window`](#watch-it-in-the-codesys-window) to watch the CODESYS window
- itself.
- 
- ## Safety
- - **No real controller.** The toolkit doesn't log in or download to a
- controller. It goes online only to CODESYS's own simulation, and every online
- call first checks that simulation mode is on.
- - **One approval covers every action.** That includes the actions that change
- or delete project code, so work on a copy of any project you can't afford to
- lose, or keep it in version control.
- - **Changes can be undone.** A checkpoint is taken when a project is opened, and
- `revert_object` puts an object back to it, including its methods and
- properties.
- - **Saved as it goes.** The project is saved after every change by default. Use
- `--no-autosave` to save only on request.
- - **The simulation can't change your project.** Editing is refused while it
- runs, and the simulation setting on the device is never saved.
- ## Configuration
- | Option | Meaning |
- | --- | --- |
- | `--codesys-path <exe>` | `CODESYS.exe` to run |
- | `--codesys-profile <name>` | Profile, e.g. `"CODESYS V3.5 SP21"` (file name in `CODESYS\Profiles`, without `.profile.xml`). A name that isn't installed is refused at start, with the installed ones listed |
- | `--codesys-additional-folder <dir>` | CODESYS's add-on folder, passed as `--additionalfolder`. SP22 installs add-ons such as Scripting there; the toolkit finds `CODESYS\AdditionalFolders\Default` by itself |
- | `--workspace <dir>` | Base folder for relative project paths (default: the working directory). Created if missing |
- | `--project <file>` | Open this project as soon as CODESYS is up |
- | `--session-dir <dir>` | Where session folders go (default: `%TEMP%\codesys-mcp-toolkit`) |
- | `--no-autostart` | Start CODESYS on the first tool call instead of at launch |
- | `--no-autosave` | Don't save after every change; use `save_project` |
- | `--viewer-port <port>` | Port of the browser workspace on 127.0.0.1 (default 5180, or the next free one) |
- | `--no-viewer` | Don't serve the browser workspace |
- | `--no-shared` | Run CODESYS in this process instead of the shared session |
- | `--attach <dir>` | Experimental: work in a CODESYS / Machine Expert window you already have open, instead of starting one. See [Working in an open window](#work-in-a-window-you-already-have-open-experimental) |
- | `--show-window` | Start CODESYS with its window instead of headless. See [Watch it in the CODESYS window](#watch-it-in-the-codesys-window) |
- ### Watch it in the CODESYS window
- By default CODESYS runs headless. With `--show-window` the server starts it with
- its normal window, so you can watch the work in any MCP client: every object the
- model creates or writes opens in its editor tab, with the new code in it.
- 
- While the simulation runs, the open editors show live values, as in CODESYS's own
- online mode:
- 
- CODESYS's scripting API has no call for opening an editor, so the toolkit uses
- CODESYS's own (undocumented) frame for it, checked on SP21 and SP22. If a CODESYS
- version doesn't have it, nothing opens and everything else works as before.
- While the server is connected, the window is for watching: the toolkit's script
- keeps running in it (that is what lets it answer CODESYS's prompts, such as a
- storage-format upgrade, the same way as headless), so CODESYS treats it as one
- long operation. The status bar says "Executing script"; its **Click here to
- CANCEL** link stops the toolkit's script, so leave it alone while you work with
- the model. When the server stops, the script ends and the window is yours to
- work in.
- The toolkit never closes the window: not when a call hangs or a dialog waits
- for an answer (answer it in the window), and not when the server stops. Close it
- yourself when you're done; the next call then starts a new one.
- ### Several CODESYS versions
- To keep SP21 and SP22 side by side, add one server entry per version, each with
- its own `--codesys-path` and `--codesys-profile`.
- The toolkit never updates a project's compiler or library versions, and
- `open_project` says when they differ from the running CODESYS. A project that
- needs a newer compiler opens, but can't compile until you open it in that
- version. Each version keeps its own devices and libraries, so a project from an
- older CODESYS may report missing libraries until you update it in the CODESYS
- window.
- ### Shared session
- Claude Desktop may start the server more than once. All processes started with
- the same options share one background session, so only one CODESYS runs and the
- panel shows the project Claude is working on. The session stops two minutes
- after the last client disconnects. Its log is `daemon-<id>.log` in
- `%LOCALAPPDATA%\codesys-mcp-toolkit`.
- ### Work in a window you already have open (experimental)
- `--attach <dir>` makes the server use a CODESYS / Machine Expert window you
- already work in, instead of starting a hidden one. It starts nothing and kills
- nothing.
- 1. Add `--attach "C:\\PLC\\attach"` to the server arguments and start the
- server. It writes `C:\PLC\attach\scripts\start_attach.py`.
- 2. In your window, open the project, then run that file with **Tools >
- Scripting > Execute Script File**. It returns at once; a UI timer polls for
- requests, so the window stays usable.
- 3. Use the `codesys` tool as usual. `open_project` on the project that is
- already open just reuses it.
- 4. To stop, create an empty file `stop.flag` in the attach folder (or close the
- window).
- The window is busy only while a request runs, for example during `compile`.
- Your own unsaved edits are saved with the next change Claude makes
- (autosave), so use `--no-autosave` if that is not what you want. If the window
- stops answering (a dialog is open), the call fails with an error and nothing is
- closed; run `start_attach.py` again if the watcher was stopped.
- ## How it works
- ```
- MCP client ── stdio ──▶ codesys-mcp-tool (Node.js)
- │ requests/<id>.json ▶ operation name + JSON arguments
- │ ◀ results/<id>.json
- │ ◀ heartbeat.json idle or busy, with a deadline
- ▼
- CODESYS.exe --noUI --runscript=watcher.py
- └─ fixed operation handlers (IronPython 2.7)
- ```
- With `--show-window`, CODESYS starts without `--noUI` and runs the same watcher.
- - **No generated code.** Requests are an operation name plus JSON arguments,
- handled by fixed functions in `watcher/mcp_ops.py`.
- - **Hang detection.** The watcher reports `busy` with a deadline. If CODESYS
- blocks past it, the server kills it and starts a fresh one on the next call.
- - **No orphans.** The watcher exits when the server process goes away.
- - **Modal dialogs** are suppressed and logged, so they can't freeze CODESYS.
- - **UTF-8** from end to end.
- - **Localised names.** Object kinds come from CODESYS type GUIDs, not names, so
- a German task folder called `Taskkonfiguration` works.
- ## Troubleshooting
- | Message | What to do |
- | --- | --- |
- | **CODESYS is still starting** | The first start after boot can take minutes. Check `codesys_status`, then try again. |
- | **`startup_failed`** or **`startup_timeout`** | Check the profile name and that CODESYS starts by hand. The error includes the last lines of `watcher.log`. |
- | **Library errors after `create_project`** ([#4](https://github.com/johannesPettersson80/codesys-mcp-toolkit/issues/4)) | The default template is brought up to the running CODESYS, so its libraries should resolve. A template you pass yourself is used as it is. If libraries are still missing, install them with the CODESYS Library Repository. |
- | **`hung`** or **`timeout`** | CODESYS was restarted. Re-open the project. With `--show-window` nothing is closed: check the window. |
- | **`dialog`** | CODESYS opened a dialog, named in the error, that a session without a window can't answer. CODESYS was stopped and restarts on the next call. Do the same step once in the CODESYS window, answer the dialog there, and try again. With `--show-window`, answer it in the window. |
- Each session folder keeps a `watcher.log`.
- ## Development
- ```bash
- npm install
- npm test # unit, bridge and tool tests (no CODESYS needed)
- CODESYS_LIVE=1 npx vitest run test/live # end-to-end against your CODESYS
- npm run build # server and the single-file panel
- ```
- The normal tests run the real watcher under CPython 3 against a fake
- `scriptengine` (`test/fake/`). Watcher code must stay valid IronPython 2.7:
- ASCII-only, no f-strings.
- To work on the panel without Claude Desktop, run the dev host, then open
- http://localhost:5199:
- ```bash
- npm run build:panel && node scripts/dev-host/run.mjs 5199
- ```
- See [CONTRIBUTING.md](CONTRIBUTING.md) to get involved.
- ## Migrating from v1
- - Everything is now an action of the one `codesys` tool.
- - Actions don't take `projectFilePath`. Call `open_project` once.
- - `create_pou`, `create_method` and `create_property` are now `create_object`
- with a `kind`.
- - `set_pou_code` is now `write_object`.
- - `compile_project` is now `compile`, and it returns the errors.
- - Read access is through actions (`read_objects`, `get_project_tree`) instead of
- resources, so it works in Claude Desktop
- ([#6](https://github.com/johannesPettersson80/codesys-mcp-toolkit/issues/6)).
- ## Acknowledgements
- The persistent-watcher design borrows ideas from
- [zbest1000/mcptoolkit-for-codesys](https://github.com/zbest1000/mcptoolkit-for-codesys)
- (op-handler registry, heartbeat, prompt handling) and
- [phobicdotno/Codesys-MCP-Master](https://github.com/phobicdotno/Codesys-MCP-Master)
- (file-queue IPC, version-safe opening). Both are MIT-licensed.
- The [Chinese README](README.zh-CN.md) was reviewed by Zhen Yang (Alfabete-spec).
- ## License
- [MIT](LICENSE)
- CODESYS is a trademark of CODESYS GmbH. This project is independent and isn't
- affiliated with or endorsed by CODESYS GmbH.